TISSEL-200

Pumps with inverter

Description
TISSEL 200 are compact pumping units composed by a centrifugal pump, with an integrated speed regulator (inverter) complete with an external pressure sensing device to be installed in one point along the system.
Sturdy and very easy to use. They are the perfect solution to get a constant pressure in every tap of the system.
The integrated speed regulator has forced ventilation and an IP 54 protection grade. It receives a single-phase alternate voltage  (230±10% V - 50/60 Hz) and supplies a three-phase alternate output voltage which supplies the motor of the pump with an IE3 performance class.
The wear of the water pump components is reduced due to the low speed of the motor during its duty life and it is progressively started and stopped.

ENERGY SAVINGS
A significant energy savings in terms of low flow rates. It is like running a lower power pump.

PROTECTIONS
- Dry running protection.
Stops the pump after a few seconds and tries to resume at intervals of time in order to check whether the water is present or not in the system.
- Running with a pressure inferior than the minimum pressure set.
Stops the pump after a few seconds (for example, when a pipe is broken).
- Currents – Voltages - Temperatures.
Limits the currents; complete with an alarm for out-of-limit voltages; protects from over-temperature and short-circuit between the output phases.
Caractéristiques

Typologie du liquide: Eau claire

Utilisations: domestique, bâtiment

Emplois: exploitant d'eau, installation de surpression, irrigation

typologie: pompes électriques avec inverseur

Famille: centrifuge

Champs des prestations:

  • Débit jusqu'à 200.00 l/min (12.0 m³/h)
  • Hauteur jusqu'à 102.00 m

Limites d'utilisation:

  • température du liquide jusqu'à +40 °C
  • Température ambiante jusqu'à +40 °C
  • Manometric suction lift up to:
   – 7 metres TS2-MK, TS2-CR
   – 9 metres TS2-PLURIJET
  • Max. working pressure:
   – 7 bar TS1-5CR 100
   – 10 bar TS2-MK, TS2-PLURIJET
  • Continuous service S1

Modèles

Modèle

Tension Mono/Tri

Puissance

kW

HP

Prestations

Q
l/min

H
m

Orifices

Asp.

Refulm.

TS2-MK 3/3

Monophase

75

1

5 ÷ 80

46 ÷ 28

1¼"

1"

TS2-MK 3/4

Monophase

11

1.5

5 ÷ 80

62 ÷ 38

1¼"

1"

TS2-MK 3/5

Monophase

11

1.5

5 ÷ 80

80 ÷ 47

1¼"

1"

TS2-MK 3/6

Monophase

15

2

5 ÷ 80

96 ÷ 56

1¼"

1"

TS2-MK 5/4

Monophase

11

1.5

5 ÷ 120

50 ÷ 20

1¼"

1"

TS2-MK 5/5

Monophase

11

1.5

5 ÷ 120

63 ÷ 25

1¼"

1"

TS2-MK 5/6

Monophase

15

2

5 ÷ 120

78 ÷ 30

1¼"

1"

TS2-MK 5/7

Monophase

18

2.5

5 ÷ 120

92 ÷ 34

1¼"

1"

TS2-MK 5/8

Monophase

22

3

5 ÷ 120

102 ÷ 40

1¼"

1"

TS2-MK 8/4

Monophase

15

2

5 ÷ 180

50 ÷ 15

1¼"

1"

TS2-MK 8/5

Monophase

18

2.5

5 ÷ 180

64 ÷ 18

1¼"

1"

TS2-MK 8/6

Monophase

22

3

5 ÷ 180

80 ÷ 20

1¼"

1"

TS2-5CR 90

Monophase

11

1.5

5 ÷ 90

78 ÷ 38

1¼"

1"

TS2-6CR 90

Monophase

15

2

5 ÷ 90

94 ÷ 45

1¼"

1"

TS2-7CR 90

Monophase

18

2.5

5 ÷ 90

110 ÷ 53

1¼"

1"

TS2-3CR 130

Monophase

11

1.5

5 ÷ 130

49 ÷ 24

1¼"

1"

TS2-4CR 130

Monophase

15

2

5 ÷ 130

65 ÷ 31

1¼"

1"

TS2-5CR 130

Monophase

18

2.5

5 ÷ 130

81 ÷ 39

1¼"

1"

TS2-6CR 130

Monophase

22

3

5 ÷ 130

97 ÷ 45

1¼"

1"

TS2-3CR 200

Monophase

11

1.5

5 ÷ 200

43 ÷ 13

1¼"

1"

TS2-4CR 200

Monophase

15

2

5 ÷ 200

57 ÷ 17

1¼"

1"

TS2-5CR 200

Monophase

18

2.5

5 ÷ 200

72 ÷ 22

1¼"

1"

TS2-6CR 200

Monophase

22

3

5 ÷ 200

86 ÷ 26

1¼"

1"

TS2-PLURIJET 5/90

Monophase

11

1.5

5 ÷ 90

78 ÷ 38

1¼"

1"

TS2-PLURIJET 6/90

Monophase

15

2

5 ÷ 90

94 ÷ 45

1¼"

1"

TS2-PLURIJET 3/130

Monophase

11

1.5

5 ÷ 130

49 ÷ 24

1¼"

1"

TS2-PLURIJET 4/130

Monophase

15

2

5 ÷ 130

65 ÷ 31

1¼"

1"

TS2-PLURIJET 5/130

Monophase

18

2.5

5 ÷ 130

81 ÷ 39

1¼"

1"

TS2-PLURIJET 6/130

Monophase

22

3

5 ÷ 130

97 ÷ 45

1¼"

1"

TS2-PLURIJET 3/200

Monophase

11

1.5

5 ÷ 200

43 ÷ 13

1¼"

1"

TS2-PLURIJET 4/200

Monophase

15

2

5 ÷ 200

57 ÷ 17

1¼"

1"

TS2-PLURIJET 5/200

Monophase

18

2.5

5 ÷ 200

72 ÷ 22

1¼"

1"